Dissolved Oxygen Analyzer JXBS3001SDOM Portable Swimming Pool Fish Pond
$ 67.18
- Description
- Size Guide
Description
Feature:1. [High Accuracy] Dissolved oxygen detector is sensitive, accurate in measurement, and with automatic temperature compensation.
2. [LCD Display] Dissolved oxygen analyzer with large TN LCD display, wich is simple to operate, to meet your various need.
3. [Portable] Specially designed for the convenience of users to carry to the scene and is divided into two parts, which is sensor and electronic unit.
4. [Digital Chip] Adopts extremely general coated dissolved oxygen electrode, and the electronic unit uses a detection circuit designed by a digital chip.
5. [Backlight Display] The digital tube backlight display is added, which can display the readings in real time, and the readings can still be clear under low light conditions.
Specification:
Item Type: Dissolved Oxygen Analyzer
Material: ABS
Product Length: Approx. 170mm / 6.7in
Width: Approx. 78mm / 3.1in
Height: Approx. 29mm / 1.1in
Battery: 3 x AAA battery (Battery Not Included)
Dissolved Oxygen Measurement Range: 0-20mg/L
Dissolved Oxygen Acuracy: ±3.0%
Dissolved Oxygen Resolution: 0.01mg/L
Temperature Measurement Range: -45~115℃
Temperature Resolution: 0.1℃
Working Temperature: 5℃~40℃
Working Humidity: 0~90% (relative humidity), non condensing
Application: Laboratories, aquariums, aquaculture, rice fields, swimming pools
Weight: Approx. 640g / 22.6oz
1. Operation Panel: There is a TN LCD display on the front of the device, and there are 6 operation buttons, namely, the on off key, the Menu key, the up key, the down key, the SCANOK key and the return key
2. Button Function Description:
Key
Introductions
Operating Mode
On Off Key
Used to turn on and off
Long Press
Menu Key
Used to eliminate the alarm when the alarm is eliminated, if the value is still in the alarm range after the alarm is eliminated 120 seconds, it will alarm again
Short Press
Used to call up the system configuration menu, or return to the main interface in the system configuration menu
Long Press
Up Key
On the menu, it is used to page up, or to decrease the value
Short Press
When inputting a value, switch to input one, ten, hundred thousand place
Long Press
Down Key
Used in the menu to scroll down or increase the value
Short Press
Switch to input one, ten, hundred thousand digits when inputting a value
Long Press
OK Key
Used to save the modified value, or enter the next level of configuration menu
Short Press
Return Key
Used to return to the previous configuration menu without saving the modified value
Short Press
Turn on the backlight
Long Press
3. Configuration Menu Introduction:
Long press the menu button to enter the configuration menu. At this time, the dissolved oxygen and temperature values are no longer displayed on the interface, but the words ConF 001 are displayed. At this time, enter the configuration menu. Press the up or down key to select different configuration sub menus
Configuration Menu
Introductions
Set Function
ConF 000
Automatic shutdown time
Modify the time of automatic shutdown, in seconds
ConF 001
Alarm switch
Whether to turn on the alarm
ConF 002
Upper alarm limit
Modify the upper limit of alarm
ConF 003
Lower alarm limit
Modify the lower limit of alarm
ConF 004
Calibrate the zero oxygen value of dissolved oxygen
Modify the probe zero point analog quantity, calibrate the probe
ConF 005
Calibrate the full oxygen value of dissolved oxygen
Modify the probe full oxygen analog quantity and calibrate the probe
ConF 006
Temperature correction value
Temperature can be corrected
ConF 007
Dissolved oxygen falling value
Increase the stability of dissolved oxygen
4. Automatic Shutdown Settings:
In the ConF 000 page, short press the OK key to enter
The option parameters are shown in the following table
Configuration Submenu
Introductions
Range
ConF 000
Automatic shutdown time setting
Adjustable
5. Alarm Setting:
On the ConF 001-003 page, short press the OK key to enter the corresponding settings
The option parameters are shown in the following table
Configuration Submenu
Introductions
Range
ConF 001
Whether to turn on the alarm
On/Off
ConF 002
Dissolved oxygen alarm upper limit
Adjustable
ConF 003
Dissolved oxygen alarm lower limit
Adjustable
The alarm trigger logic is to trigger an alarm when the data is greater than the upper limit of the alarm or less than the lower limit of the alarm. The screen will indicate the alarm icon and the cause of the alarm (over the upper limit or the lower limit), and the buzzer will alarm, 120 seconds after the alarm is cleared, if the value is still within the alarm range Then the alarm will continue
6. Dissolved Oxygen Value Calibration:
In the ConF 004-005 page, short press the OK key to enter the corresponding settings
The option parameters are shown in the following table
Configuration Submenu
Introductions
Range
ConF 004
Calibration zero
Adjustable
ConF 005
Full calibration value
Adjustable
After entering, the displayed value is the current calibration value. You can view the analog value in the current environment by scrolling up and down. Press the OK key to write the current analog value into the current calibration value and return to the previous page
7. Temperature Correction:
On the ConF 006 page, short press the OK key to enter
The option parameters are shown in the following table
Configuration Submenu
Introductions
Range
ConF 006
Correct the temperature value
Adjustable
The displayed value is the modified value added to the temperature, which can be modified by flipping up and down keys.
8. Dissolved Oxygen Fall Back Value:
In the ConF 007 page, short press the SCAN (OK) key to enter
The option parameters are shown in the following table
Configuration Submenu
Introductions
Range
ConF 007
Increase the stability of dissolved oxygen
Adjustable
After entering, the displayed value is the dissolved oxygen drop value, which can be modified by the up and down keys
How To Use:
Operation method:
1. Switch machine
Press and hold the power button for 1 second, the light in the upper right corner of the keypad will flash twice, and the device will turn on
When the device is turned on, press and hold the power button for 3 seconds, the light in the upper right corner of the keypad will be on, and the device will shut down
2. Turn on the backlight
Long press the return key to turn on the backlight, and then long press again to turn it off
Probe use steps:
1. Unscrew the membrane cap, rinse the electrode membrane cap and metal tube with deionized water and drying
2. Inject about three quarters of the volume of electrolyte into the membrane cap, and then tighten the membrane cap. A small amount of electrolyte overflow during this process is a normal situation. After tightening, ensure that there are no bubbles in the front of the electrode and between the electrode and the membrane. There is no liquid interval, otherwise it needs to be reinstalled
3. Connect the electrode to the opened instrument, and make the electrode polarize in the air for 1 hour
4. Test after calibration according to the electrode calibration instructions
5. When replacing the electrolyte, membrane cap or not using it for more than 24 hours, it needs to be repolarized for 1 hour
Electrode calibration:
1. Zero oxygen calibration: Pour 1 pack of reagents into about 100mL of water and stir evenly to obtain oxygen free water. Immerse both ends of the motor side in oxygen free water, and after the reading is stable (reading fluctuation is less than 0.1), perform zero oxygen calibration (zero oxygen reagent can be maintained in the air for 24 hours, and needs to be reconstituted if it exceeds 24 hours)
2. Full oxygen calibration: place the electrode measuring end in the air (suitable for general users) or immerse it in saturated dissolved oxygen deionized water with constant temperature (suitable for users with higher accuracy requirements), and wait until the reading is stable (reading fluctuates less than 0.1), perform full oxygen calibration
Package List:
1 x Dissolved Oxygen Detector With Probe (Battery Not Included)
1 x Dissolved Oxygen Electrode Tip
1 x 30ML Electrolyte
5 Pack x Zero Oxygen Reagents (5g Per Pack)
1 x Sandpaper
1 x Manual
Note:
1. When the electrode is calibrated and measured, because the electrode needs to consume oxygen, it is necessary to ensure the flow of the measuring water body (20‑30cm/s), otherwise it will cause low readings; when using, pay attention to protect the electrode membrane head to avoid contact with hard objects or pointed objects. Items, if the membrane head leaks, it should be replaced in time
2. The filling liquid in the electrode should be replaced every 20‑30 days according to the frequency of use, or the electrolyte should be replaced in time when the electrode display shows a significant deviation
3. The electrolyte and zero oxygen reagent should be stored in a dry and ventilated place at room temperature
We accept PayPal .
We ship item to your PayPal verified address.
Payment must be received within 3 days from the date of purchase.
All the items will be dispatched within one business day by Airmail after the payment is clear.
Most times you will receive your order within 10-30 business days after we transfer your package to the delivery company. We cannot guarantee the delivery timeframe if the post office has any unexpected delays due to holiday, weather, customs, or other conditions. Some countries like Russia, Brazil, or some European countries may take up to 50 days or longer for delivery.
We appreciate your patience if you haven't received items in 30 days(Russian customers may need more patience by reason of the local delivery system and/or customs). If you are concerned in any way, please feel free to contact us via ebay message
instead of leaving negative/neutral feedback or opening a dispute
.
We will do our best to solve any problem(resend or refund any missing item).
Customs duty is obligation and liability of
citizen
s in your country, so buyer should be responsible for any tax and custom duty incurred. Generally, the delay or failure delivery is sometimes caused by the policy of different customs.
1. Our listing price includes the value of goods,packaging cost,and export
taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3.
T
he duties are buyers' responsibility
.Please check with your country's
customs office determine what these additional costs will be prior to your
purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.
1. Any questions,
pls. contact us via ebay message or email us.
We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.
2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "
5
" in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better.
We strive to keep all our customers satisfy.
We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.